Free shipping on tanks and on orders over $500 Across Canada since 2015 · 1-877-306-2146

One litre a minute is 1,440 litres a day.

A slow well usually makes enough water. It makes it at the wrong speed. The Trickle-Fill System banks the well’s output around the clock so the house can draw it at full pressure. Six sizes, 440 to 1,950 litres, pump included.

Trickle-Fill System: ribbed storage tank with float valve and DAB pump

Do the arithmetic

A well that recovers 1 litre a minute gives 1,440 litres in a day.

A household of four uses roughly 900.

One shower asks for about 8 litres a minute, right now.

The daily total is fine. The rate is the problem: the house wants water several times faster than the well gives it, a few minutes at a time.

A storage tank separates the two rates. The well fills the tank at its own pace, around the clock. The house draws from the tank as fast as it likes.

How it worksFour states, no controls to set

Well water pouring into the tank through the float valve

The well fills the tank

Water enters through the float valve at whatever rate the well can give.

Tank full, float raised, valve closed

Full tank, valve closed

The float lifts and shuts the valve mechanically. Nothing to program.

Water flowing from the tank to the pump

Open a tap, the pump wakes

The DAB pump senses demand and draws from the tank, not the well.

Excess water leaving through the overflow pipe

Overflow to drain

If the tank ever overfills, the 2 in overflow carries the excess to a drain by gravity.

What you getOne system, pump included

  1. HDPE storage tankRibbed vertical slimline or cylindrical, 440 to 1,950 L, with an 8 in lid.
  2. Float-operated fill valveCloses as the water rises. Mechanical, no power, no sensor to fail.
  3. DAB Esybox Mini 3 pumpVariable-speed with a built-in VFD, 120/240 V. Starts when a tap opens, holds a set pressure, stops when the tap closes.
  4. Vent, overflow and shut-offs2 in vent you can pipe outside, 2 in gravity overflow, isolation valves on the inlet and the pump feed.

Everything on the tank ships fitted, and the pump comes with it. Your installer supplies the connecting pipe: the well line in, the house line out, and the overflow to a drain.

DAB Esy-line pumps bought from this store carry two years from the manufacturer plus a third year from us.

Six sizes440 to 1,950 litres

440 LUpright116 US gal
760 LSlimline200 US gal
910 LUpright240 US gal
1,500 LSlimline395 US gal
1,600 LSlimline420 US gal
1,950 LSlimline515 US gal

Work out your own number: the well’s recovery rate in litres a minute, times 1,440. If that is comfortably more than the house uses in a day, storage fixes the problem, and a day of use is a sensible tank size: roughly 450 L for two people, 900 L for four. If it is less, storage alone will not fix it, and we will tell you so.

DocumentsPDF downloads

The installation, operation and maintenance manual covers choosing the place, the connections, start-up and upkeep.

Spec sheets by size: 440 L 760 L 910 L 1,500 L 1,600 L 1,950 L

Ask about itWe call back the same business day

In your message, tell us where you are, how many people are in the house, and anything you know about the well’s recovery rate.

Questions

How do I find my well’s recovery rate?

Your well record usually lists a tested yield, and most provinces keep well records online. A licensed well contractor can run a recovery test for a current figure. Send us whatever you have.

Will this help if my well runs low in August?

Only if the well still makes more water over a day than you use. The tank banks the slow hours; it cannot make water the well does not have. Call with the recovery rate and we will be straight with you.

Does it treat the water?

No. It stores and pressurizes. Whatever treatment your well water needs today it still needs; the pump simply feeds it from the tank instead of straight from the well.

What happens to my well pump?

It stays. It now fills a tank through a float valve instead of pressurizing the whole house, so it runs at the well’s own pace and stops when the tank is full.

Where does the system go?

A basement, utility room or pump house with a drain for the overflow and a 120 or 240 V supply for the pump. The 2 in vent can be run outside. The tallest sizes stand 90 in with the vent fitted.

Tell us about the well. We will tell you which size.

Recovery rate if you know it, number of people in the house, and where you are. That is enough for a real answer.