Below Ground Surge, Potable, 6000 USG, 4x 1500 USG Design

This below ground surge system is designed to meet Canadian plumbing codes and CSA standards for rainwater harvesting CSA B805. The overall system design employs a multi-barrier approach to water quality. The first step is the pre-filter. The second step is the rainwater tank design. The third step is the water treatment system. Cleanflo systems are designed from “roof to tap” with attention to every detail of your rainwater harvesting system. When you purchase the complete system from Rainwater Collection Supply, it is part of a complete package that we will provide support and service for the life of the system.

This rainwater harvesting system is designed as a primary source of water for potable purposes, such as drinking, cooking, bathing, toilets, and laundry, with a backup water source from hauled bulk potable water if the rainwater tank is empty. The system will provide water for water uses Tier: R4 – Potable Domestic.

Original price was: $150.00.Current price is: $0.00.

Description

Our Free Below Ground Surge, Potable, 6000 USG, 4 X 1500 USG Design

Roof

The below ground surge system will be harvesting rain from one building; the roof is asphalt. When using the rainwater for potable water, the roof should be NSF P151 approved or coated with a NSF P151 approved coating.

Gutter, Downpipes, and Conveyance Piping

The gutters, downpipes, and conveyance piping are sized based on specifications from the designs. When using the rainwater for potable water, the gutter, downpipe, and conveyance piping should be NSF P151 approved or coated with a NSF P151 approved coating.

Pre-Filter

The system will require two (2) pre-filters. These pre-filters operate as both a first flush diverter and pre-filter, with a filter mesh size of 320 microns. The full cross-section (pipe diameter) of the rainwater drainage system remains continuously open, and there are no reductions in the cross-section of this appliance in which dirt or water can collect.

Rainwater Tank / Cistern

This below ground surge system will provide a total of 6000 USG of rainwater storage, with a total of four (4) below-ground tanks, made of polyethylene. Each tank is 1500 USG. The rainwater tank is designed to provide safe storage of rainwater, which improves water quality because of its design and function. The calming inlet prevents agitation of settled fine dust, the skimming overflow removes floating particles, and the floating filter ensures water is drawn into the pump from approximately 150 mm (6.0″) below the surface of the water.

Water Pumping and Treatment System

Cleanflo determined the water demand to be 10 GPM @ 60 PSI. This will be pumped by a multi-stage booster pump powered by VFD. The treatment will be three stages to ensure water is safe and no staining on fixtures. Stage one is a sediment filter of 15 microns which provides a self-cleaning flush to drain. Stage two is a 10 carbon filter. Stage three is a 1 micron sediment filter. Stage four is an ultraviolet sanitation system NSF 55 Class A.

Water Quality and Treatment

Cleanflo designed this system to produce water that is safe for CSA B805 R4 uses; namely potable domestic.